Blackland Research and Extension Center

Texas AgriLife Research
Leading in Land and Water Solutions - Serving Texas 100 Years
Center photo

Reducing Contamination by Improving Household Wastewater Treatment

B.L. Harris, D.W. Hoffman and F.J. Mazac, Jr.

  1. Do you have an on-site wastewater disposal system (septic tank) on your land?
  2. Is your septic tank less than 50 feet from a water well?
  3. Do you pump your septic tank on a regular basis (about once a year if you have a garbage disposal or once every 3 to 5 years if you do not)?
  4. Do you dump grease, oils or leftover household chemicals down the drain?
  5. Have you noticed wet or smelly areas in your yard?
  6. Is your septic tank capacity too small to accommodate the number of people in your household, or has an additional restroom been added to your home?
  7. Do you have non-sewage water entering your septic system or drain field?

If these questions create doubt about the safety of your management practices, this publication will provide helpful information.

Household Wastewater Treatment

Virtually all farms use a septic system or similar on-site wastewater treatment system. While these systems are generally economical and safe, household wastewater can contain contaminants that degrade water quality for such uses as drinking, stock watering, food preparation and cleaning.

Potential contaminants in household wastewater include disease-causing bacteria, infectious viruses, household chemicals, and excess nutrients such as nitrate. Viruses can infect the liver, causing hepatitis, or infect the lining of the intestine, causing gastroenteritis (vomiting and diarrhea). If coliform organisms (a group of indicator bacteria) are found in well water, the water is potentially dangerous for drinking and food preparation. Septic systems are a potential source of this pollution, as are livestock yards.

A properly installed and maintained system for treating and disposing of household wastewater will minimize the impact of that system on ground water and surface water. State and county codes specify how wastewater systems must be designed, installed and maintained. All new systems must be installed by a state certified installer and inspected by a state certified inspector prior to use. At a minimum, follow the Texas Natural Resource Conservation Commission codes for design and construction, but also consider whether the minimum requirements are sufficient at your site.

A glossary of terms at the end of this publication will clarify terminology. This publication covers the following topics:

  1. Septic tanks/soil absorption systems
  2. Quantity of wastewater
  3. Quality of wastewater
  4. Collection of wastewater
  5. Treatment systems
  6. Disposal system
  7. Assistance with failing systems or new designs
  8. Evaluation table

Septic Tanks/Soil Absorption Systems

The most common form of on-site wastewater treatment is a septic tank/soil absorption system. In this system, wastewater flows from the household sewage lines into an underground septic tank. The following then occurs:

householdsystem.gif

Figure 1. Typical household wastewater treatment system with problems. Illustration by Andy Hopfensperger, University of Wisconsin-Madison Department of Agricultural Engineering.

Figure 1 shows a typical household system for wastewater generation, collection, treatment, and disposal. While such systems may be called by various names (such as septic tanks or subsurface treatment and disposal systems), they are similar. In this discussion the term septic tank is used. Note the list of options below each part of the diagram. You may wish to circle the parts found in your system. The 'leakage', 'overflow', 'infiltration' and 'clearwater' components represent possible problems with the system. Unfortunately, these problems are often difficult to recognize. Over-flow from systems may be noticed as wet spots, odors and changes in vegetation cover. Water entry (infiltration and clear water) will be more difficult to detect. To help detect any water entry, trace where the floors drain, the roof drains, the foundation drains, and where sumps are directing outside water into the treatment system. Leakage from the collection and treatment system, as well as infiltration of water into the system through unsealed joints, access ports and cracks, can be very difficult to assess. The flow chart at the bottom of the box follows the flow of wastewater and sludge through the treatment system.

Quantity of Wastewater

The best strategy is to minimize the volume of household wastewater entering the treatment system. This is important because less flow (volume) means better treatment, longer system life, and less chance of overflow. Less volume also lowers costs by reducing the number of times the holding tank must be emptied.

The quantity of water used depends upon the number of people using the dwelling, their water use rates, and the maintenance of the water supply system. Average water use in rural households is 40 to 50 gallons per person per day. With low-use fixtures and individual awareness and concern, a reduction to fewer than 25 gallons per person per day is possible. However, even conservative use by several people may exceed the capacity of the wastewater treatment system.

Reducing the volume of water entering the system will improve treatment by increasing the time the waste spends in the system, thus providing more time for settling, decomposition, aeration and soil contact.

Consider the following ways to minimize water use.

aerationtank.gif

Figure 2. Aeration tank of a household aerobic treatment system. Source: Onsite Domestic Sewage Disposal Handbook, MWPS-24, Midwest Plan Service, 1982.

Keep in mind that your family's awareness of your water use and how it can be reduced is as important as the use of water conservation devices.

Quality of Wastewater

Domestic wastewater usually contains relatively small amounts of contaminants - less than 0.2 percent (i.e., it is 99.80 percent 'pure' water), but even small amounts of contaminants can make a big difference in the usefulness of the water.

Contaminants found in wastewater include the following:

Here are some ways to improve wastewater quality:

Collection of Wastewater

Collect all waste that needs treatment and minimize the loss of untreated waste. Leaking pipes or treatment tanks can allow wastewater to return to the local water supply without adequate treatment. Exclude from the treatment system water that does not need treatment or disposal.

Infiltration of clear water overloads the system and dilutes the wastes. Do not allow rainwater or water from basement floor drain sumps, foundation drains or roof drainage to add to your waste water volume. Divert clean water away from the house, any wells, and any wastewater treatment system.

Treatment Systems

Make wastewater suitable for treatment and disposal in the soil by reducing the concentration of contaminants in the wastewater.

Septic tanks retain most of the suspended solids (sludge) and scum from wastewater. In the tank, bacteria digest and compact the sludge. The partially treated water moves to additional treatment or disposal, for example, in the soil absorption field.

The design and construction of septic tanks influence their water tightness and effectiveness at retaining sludge and scum. Multiple tanks or chambers in series can improve sludge and scum removal. Gas deflectors and filter screens or inclined-plate settling units help to minimize solids entering the drain field. Tanks should be sized to accommodate at least 24 hours of wastewater flow while still allowing for sludge and scum retention. Pumping the tank before it is more than one-third filled with scum and sludge (generally every 3 to 5 years) improves the functioning of the system. When the tank is pumped, you should have the baffles checked and also check for tank leaks. Septic tanks should be made of reinforced concrete, polyethylene or prefabricated fiberglass.

Aerobic (oxygen using) biological systems, which are considered packaged systems, treat wastewater better than the typical anaerobic (no oxygen) septic units, thus improving solids separation, releasing volatile chemicals, and reducing sludge volume. These systems are, however, more expensive to operate and maintain and are more often subject to problems caused by changes in wastewater quality or environmental conditions. Aerobic systems are often used because they produce high quality effluent which may be disposed of through conventional trenches or drip irrigation, or sprayed on top of the ground.

If you have an aerobic system, you should have a maintenance person inspect the unit three times each year. The maintenance person should check the aeration mechanism, the disinfection unit (tablet chlorinator), and other critical aspects of the unit.

Between inspections you should check the tablet chlorinator for chlorine tablets. If there are no tablets, fill the chlorinator immediately. An empty chlorinator increases the chance that disease causing organisms will come into contact with people.

Additional treatment after wastewater has passed through the septic system can reduce the concentration and amount of contaminants in the wastewater and make it suitable for disposal.

Aerobic systems may be used for additional treatment of septic tank effluent, and these systems can yield a better quality effluent suitable for more disposal options.

sandfilter.gif

Figure 3. Buried sand filter. Source: Onsite Domestic Sewage Handbook, MWPS-24, Midwest Plan Service, 1982.

Sand filters also improve the quality of wastewater after septic tank pretreatment. Effective treatment involves aerobic biochemical activity as well as physical filtration. Filters consist of 2 to 5 feet of sand (or other media) in a bed equipped with a distribution and collection system. Wastewater is applied by dosing, and it may be recirculated to improve treatment.

Filters should be designed according to the pretreatment system used, the quality of the wastewater, the hydraulic loading rate, the dosing frequency, the temperature, and the distribution and collection systems used. Filter maintenance includes resting, occasional raking, removal of clogged or crusted surface media, filter media replacement, and attention to dosing equipment.

Wastewater treated in such systems is generally lower in bacteria, nitrogen, phosphorus, oxygen demand, suspended solids and organic matter. The amount of reduction depends on the design of the system.

A disinfection unit is a system that kills disease-causing microorganisms in wastewater, and is used when discharge on the surface is permitted. Chlorine, iodine, ozone and ultraviolet light systems are available to treat good quality effluent, such as that from properly functioning aerobic units and sand filters.

Disposal Systems

To reduce the risk of wastewater contaminating water supplies, disperse effluent and maximize its contact with soil and plant roots.

Discharging treated or untreated wastewater from private systems directly to surface waters or ditches is illegal in Texas. Illegal wastewater discharges or wastewater surfacing above the drain field can endanger your health as well as the health of others in your community.

Subsurface Treatment Systems

Subsurface treatment and disposal, using soil absorption systems (trenches, beds, or mounds), is the common disposal system following septic tanks. There are, however, sites where soil absorption systems will not function properly and will endanger ground water quality. Unsuitable sites are those with impermeable soils, shallow rock, shallow water tables, or very permeable soils such as a sand or gravelly soil.

Suitable sites are those with deep, well-drained, well-developed, medium-textured soils (such as silt loam and loam). Soil beneath the disposal area must be unsaturated to provide adequate treatment. Unsaturated soil allows the effluent to remain aerobic and to flow through tighter soils, thereby filtering contaminants and giving soil microbes longer contact time with soil organic matter. Approximately 4 feet of unsaturated soil should be maintained beneath the disposal system to adequately remove pathogens and organic matter from wastewater.

Disposal systems that are downslope and far from the water well will better protect your water supply from possible contamination from wastewater.

Surface Treatment Systems

When compared to subsurface treatment systems, surface treatment systems promote more evapotranspiration (removal of effluent by evaporation and loss through plants). Increased evapotranspiration decreases the amount of treated effluent that can reach the water supply. However, disposal systems that apply the treated effluent directly on the ground surface must have an approved method of treatment and should disinfect the effluent before application. Keep the following application strategies in mind:

Assistance with Failing Systems or New Designs

If you suspect your household wastewater treatment system is backing up or your distribution system is clogged, first contact a plumber or treatment system installer, who may have suggestions for extending the life of your system. The county public health office is the location to visit for permits to repair or replace a wastewater treatment system. Take the following steps to reduce any risk of contaminating ground water:

A properly designed, constructed and maintained septic system can effectively treat wastewater for many years, but it requires routine maintenance. For additional information on septic systems, contact your county Extension agent, local health department, or Texas Natural Resource Conservation Commission On-Site Wastewater/Agricultural Division (512) 463-8260.

Evaluation Table

The following table can be used to help agricultural producers and rural homeowners determine the risk that drinking water on a given property may be contaminated because of the management practices being used. For each category on the left that is appropriate, read across to the right and circle the statement that best describes conditions on your land. Allow 15 to 30 minutes to complete the table, and skip any categories that do not apply. Note any high risk ratings and take appropriate actions to remedy them. Strive for all low or low-moderate risk ratings.

Assessing the Risk of Ground Water Contamination from Household Wastewater Treatment

Glossary

Approved disposal site: A site for land application of wastewater or tank pumpage that meets state standards of the Texas Natural Resource Conservation Commission (TNRCC).

Cesspool: Covered excavation in the ground that receives sewage directly from a building's sanitary drainage system. It is designed to retain the organic matter and solids and to permit liquid to seep into the soil. Cesspools are not allowed for construction and/or use in the state. They are considered unsuitable on-site wastewater disposal methods.

Clear water infiltration: Entry of water that does not need treatment into a treatment system; clear water may enter through tile drainage, unsealed joints, access ports and cracks.

Design capacity: Maximum volume of liquid that can be treated in a particular wastewater treatment system. For systems that include subsurface wastewater disposal and distribution, capacity is also based on the soil's ability to accept and treat sewage effluent. In filling out the worksheet, if you do not know the design capacity of your system, use 150 gallons per bedroom per day as an estimate.

Effluent: Liquid discharged from a septic tank or other sewage treatment tank.

Holding tank: An approved watertight receptacle for collecting and holding sewage.

Hydraulic loading rate: The volume of waste discharged per unit area per unit time.

Off-site disposal: Disposal of wastewater or sludge at a municipal treatment plant or other approved disposal site.

Scum: Floatable solids, such as grease and fat.

Seepage pit (dry well): Underground receptacle constructed to permit disposal of septic tank effluent, treated wastes or clear wastes by soil absorption through its bottom and walls. Seepage pits are not allowed for construction and/or use in the state. They are considered unsuitable on-site wastewater disposal methods.

Sludge: Settleable, partially decomposed solids resulting from biological, chemical or physical wastewater treatment.

Contacts and References

For additional information, contact your county Extension agent or Natural Resources Conservation Service office.

Texas A&M System Brand
Blackland Research and Extension Center · Grassland, Soil and Water Research Laboratory · USDA-NRCS · EPA Region 6
Compact With Texans · Privacy Statement · Statewide Search · Accessibility Policy (PDF Reader)
State Link Policy · Report Fraud, Waste and Abuse · Texas Homeland Security · Open Records/Public Information
© 2009 All Rights Reserved · Webmaster